Product Center

News

Cold applied tape is widely used in oil and gas pipeline anti-corrosion fields.
There are a variety of factors at play. Here are a few in not particular order o...
I have used both hot(heat shrinkable sleeves) and cold applied bitumen based wra...

FAQ

Black,Red,Green,Yellow,Blue,White,Clear color heat shirnk tube
the diffrences bettwen cold applied tape and anti-corrosive tape.
the diffrences bettwen heat shrinkable tubular sleeves and heat shrinkable warpa...

Tags

Contact Us

 Adress: Meiyan,Wujiang,Suzhou,Jiangsu,China
 Tel: +86-512-63672926
 Fax:+86-512-63672818
 Email:jimmy@heatshrinkfactory.com
Email:tongjinpoly@gmail.com
Whatsapp:+86-13913054439
 Skype:tongjinpoly

Heat shrink Tubing & cold shrink Tubing

36KV Heat Shrink Cable Accessories

36KV Heat Shrink Cable Accessories
36KV Heat Shrink Cable Accessories
36kv heat shrink cable termination and joints kits widely used in electricity supply systems under 36kv in oil refinery,metallurgy, railway, ports and other area.

*Unit:PC
*Temperature:125℃
*Voltage:36kv
*Color:black,red
*Size Range:50-400mm2

36kv heat shrink cable termination and joints kits widely used in electricity supply systems under 36kv in oil refinery,metallurgy, railway, ports and other area.

PRODUCT DESCRIPTION

1.Introduce

36KV heat shrink power cable terminations and joints are consist of anti-tracking tube,heat shrink protected tube,breakout,rain shed and stress control tube,widely used in electricity supply systems under 36kv in oil refinery,metallurgy, railway, ports and other area.

2.Technical Data

Property

Test Method

Result

1min Power frequency test

105kV 1min no flash over,no strick

 no flash,no strick no flash over

Partial discharge test

The magnitude of discharge at 39kv shall not exceed 20pc

The magnitude of the discharge of the combination sample didn't exceed 4pc at 39kv

 Cyclic load test

5h heating,conduction 

temperature 95℃,3h colling

Subjected to 3 time

 Cyclic load test

Impulse voltage withstand test

Neither breakdown nor  flashover shall occur at 10 positive and negative  impulses of 250kv

No breakdown nor flashover occurred on the combination sample at 10 positive and 10 negative impulses of 250kv

DC negative polarity voltage withstand for 15min

Neither breakdown nor flashover shall occur at 156kv for 15 min

No breakdown nor flashover occurred  on the combination samples at 156kv for 15 min

4h Power frequency test

104KV 4h no flash over,no strick

 no strick,no flash over

 

3.Size and Type

Size

Type

Cable Range

36kv NRSY -3/1

 

INDOOR TERMINATION FOR 

36kv 3 CORES CABLE

35-50mm2

36kv NRSY -3/2

70-120mm2

36kv NRSY -3/3

150-240mm2

36kv NRSY -3/4

300-400mm2

36kv WRSY -3/1

 

 OUTDOOR TERMINATION FOR 

36kv 3 CORES CABLE

 

35-50mm2

36kv WRSY -3/2

70-120mm2

36kv WRSY -3/3

150-240mm2

36kv WRSY -3/4

300-400mm2

36kv JRSY -3/1

 

STRAIGHT THROUGH JOINT
FOR 36kv 3 CORES CABLE

35-50mm2

36kv JRSY -3/2

70-120mm2

36kv JRSY -1/3

150-240mm2

36kvJRSY -1/4

300-400mm2

36kv NRSY -1/1

 

INDOOR TERMINATION FOR 

36kv SINGLE CORE CABLE

35-50mm2

36kv NRSY -1/2

70-120mm2

36kv NRSY -1/3

150-240mm2

36kv NRSY -1/4

300-400mm2

36kv WRSY -1/1

OUTDOOR TERMINATION FOR 

36kv SINGLE CORE CABLE

35-50mm2

36kv WRSY -1/2

70-120mm2

36kv WRSY -1/3

150-240mm2

36kvWRSY -1/4

300-400mm2

36kv JRSY -1/1

STRAIGHT THROUGH JOINT
FOR 36kv SINGLE CORE CABLE

35-50mm2

36kv JRSY -1/2

70-120mm2

36kv JRSY -1/3

150-240mm2

36kv JRSY -1/4

300-400mm2